Comparing the clinical and economic effects of clinical examination, pulse oximetry, and echocardiography in newborn screening for congenital heart defects: A probabilistic cost-effectiveness model and value of information analysis

Lookup NU author(s): Dr Christopher Wren

Downloads


Abstract

Objectives: Congenital heart defects (CHD) are an important cause of death and morbidity in early childhood, but the effectiveness of alternative newborn screening strategies in preventing the collapse or death-before diagnosis-of infants with treatable but life-threatening defects is uncertain. We assessed their effectiveness and efficiency to inform policy and research priorities. Methods: We compared the effectiveness of clinical examination alone and clinical examination with either pulse oximetry or screening echocardiography in making a timely diagnosis of life-threatening CHD or in diagnosing clinically significant CHD. We contrasted their cost-effectiveness, using a decision-analytic model based on 100,000 live births, and assessed future research priorities using value of information analysis. Results: Clinical examination alone, pulse oximetry, and screening echocardiography achieved 34.0, 70.6, and 71.3 timely diagnoses per 100,000 live births, respectively. This finding represents an additional cost per additional timely diagnosis of 4,894 pound and 4,496,666 pound for pulse oximetry and for screening echocardiography. The equivalent costs for clinically significant CHD are 0,489 and 06,013, respectively. Key determinants of cost-effectiveness are detection rates and screening test costs. The false-positive rate is very high with screening echocardiography (5.4 percent), but lower with pulse oximetry (1.3 percent) or clinical examination alone (.5 percent). Conclusions: Adding pulse oximetry to clinical examination is likely to be a cost-effective newborn screening strategy for CHD, but further research is required before this policy can be recommended. Screening echocardiography is unlikely to be cost-effective, unless the detection of all clinically significant CHD is considered beneficial and a 5 percent false-positive rate acceptable.


Publication metadata

Author(s): Griebsch I, Knowles RL, Brown J, Bull C, Wren C, Dezateux CA

Publication type: Article

Publication status: Published

Journal: International Journal of Technology Assessment in Health Care

Year: 2007

Volume: 23

Issue: 2

Pages: 192-204

Date deposited: 21/07/2011

ISSN (print): 0266-4623

ISSN (electronic): 1471-6348

Publisher: Cambridge University Press

URL: http://dx.doi.org/10.1017/S0266462307070304

DOI: 10.1017/S0266462307070304


Altmetrics

Altmetrics provided by Altmetric


Share