Toggle Main Menu Toggle Search

Open Access padlockePrints

Review: I-131 activity for remnant ablation in patients with differentiated thyroid cancer: A systematic review

Lookup NU author(s): Dr Ujjal Mallick

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

Context: Radioiodine ablation of the thyroid remnant after thyroidectomy is commonly performed in the management of patients with differentiated thyroid cancer. Although many centers administer an activity of 100 mCi, there is uncertainty over using a lower activity. Objective: A systematic review of the published literature was used to compare the success rates of remnant ablation using approximately 30 mCi with approximately 100 mCi (1.1 vs. 3.7 GBq). Data Sources: Data were obtained from MEDLINE and EMBASE for the years 1966 to March 2006. Study Selection: All studies that reported rates of successful ablation associated with approximately 30 or approximately 100 mCi of radioiodine were reviewed. Data Extraction: Studies were based on reviews of patient case notes (n = 41), prospective cohorts (n = 12), and randomized trials (n = 6). We obtained the success of thyroid remnant ablation according to different administered activities of radioiodine. Where a study reported on two or more activities, the risk ratio of having a successful ablation (similar to 30 vs. similar to 100 mCi) was calculated and combined in a meta-analysis. Data Synthesis: Observational studies confirmed the high ablation success rate (similar to 80%) using approximately 100 mCi, although 22% of studies reported a rate of 90% or greater. The pooled ablation success rate in these studies was 10% lower using 30 mCi compared with 100 mCi (95% confidence interval, 3-17%; P = 0.01). The meta-analysis of the randomized trials produced equivocal results. For example, the rate of successful ablation in patients given 30 mCi was 8% lower compared with 100 mCi (95% confidence interval, 29% lower or up to 20% greater, P = 0.58), consistent with there being no difference or that 30 mCi is much less effective. Conclusions: From the published data, it is not possible to reliably determine whether ablation success rates using 30 mCi are similar to using 100 mCi. Large randomized trials are needed to resolve the issue and guide clinical practice.


Publication metadata

Author(s): Hackshaw A, Harmer C, Mallick U, Haq M, Franklyn JA

Publication type: Review

Publication status: Published

Journal: Journal of Clinical Endocrinology and Metabolism

Year: 2007

Volume: 92

Issue: 1

Pages: 28-38

ISSN (print): 0021-972X

ISSN (electronic): 1945-7197

URL: http://dx.doi.org/10.1210/jc.2006-1345

DOI: 10.1210/jc.2006-1345


Share