Browse by author
Lookup NU author(s): Dr Sadettin Sali
Full text for this publication is not currently held within this repository. Alternative links are provided below where available.
A matched triaxial device is developed and constructed to measure the transfer impedance of braided coaxial cables at microwave fresquencies. Full design principles of the device are developed and are presented in detail. The device is particularly suited for shielding measurements at frequencies up to 3.5 GHz, for which no comparable technique exists. The performance of the device is fully evaluated both theoretically and by measurements. The accuracy of the device is studied by comparing the results against those obtained from the low frequency triple coaxial apparatus recommend by the International Electrotechnique Committee and using well known theoretical models. © IEE, 2004.
Author(s): Sali S
Publication type: Article
Publication status: Published
Journal: IEE Proceedings: Science, Measurement and Technology
Year: 2004
Volume: 151
Issue: 4
Pages: 235-243
ISSN (print): 1350-2344
ISSN (electronic): 1751-8830
Publisher: The Institution of Engineering and Technology
URL: http://dx.doi.org/10.1049/ip-smt:20040103
DOI: 10.1049/ip-smt:20040103
Altmetrics provided by Altmetric