The performance of a Brayson cycle, a hybrid gas turbine cycle, has been examined to establish the effect of air cooling and heat exchanger effectiveness on the cycle efficiency and specific power. The air-cooled heat exchanger was optimized to produce the maximum net efficiency for the specified minimum cycle temperature. The cycle performance was shown to be adversely influenced by the air cooling as it reduced both the specific power and efficiency. The heat exchanger effectiveness was shown to have a secondary impact on the performance parameters. An additional optimization of the heat exchanger at minimum volume is also presented to act as a benchmark against which the performance of the heat exchanger in the optimized cycle can be compared.
Author(s): Frost TH, Anderson A, Agnew B, Potts I
Publication type: Article
Publication status: Published
Journal: Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Year: 2003
Volume: 217
Issue: 3
Pages: 233-238
ISSN (print): 0957-6509
ISSN (electronic): 2041-2967
Publisher: Professional Engineering Publishing Ltd.
URL: http://dx.doi.org/10.1243/095765003322066466
DOI: 10.1243/095765003322066466