Browse by author
Lookup NU author(s): Professor John-Paul TaylorORCiD, Dr Dag Aarsland
Full text for this publication is not currently held within this repository. Alternative links are provided below where available.
© 2020 The Author(s)Deep learning (DL) methods have in recent years yielded impressive results in medical imaging, with the potential to function as clinical aid to radiologists. However, DL models in medical imaging are often trained on public research cohorts with images acquired with a single scanner or with strict protocol harmonization, which is not representative of a clinical setting. The aim of this study was to investigate how well a DL model performs in unseen clinical datasets–collected with different scanners, protocols and disease populations–and whether more heterogeneous training data improves generalization. In total, 3117 MRI scans of brains from multiple dementia research cohorts and memory clinics, that had been visually rated by a neuroradiologist according to Scheltens’ scale of medial temporal atrophy (MTA), were included in this study. By training multiple versions of a convolutional neural network on different subsets of this data to predict MTA ratings, we assessed the impact of including images from a wider distribution during training had on performance in external memory clinic data. Our results showed that our model generalized well to datasets acquired with similar protocols as the training data, but substantially worse in clinical cohorts with visibly different tissue contrasts in the images. This implies that future DL studies investigating performance in out-of-distribution (OOD) MRI data need to assess multiple external cohorts for reliable results. Further, by including data from a wider range of scanners and protocols the performance improved in OOD data, which suggests that more heterogeneous training data makes the model generalize better. To conclude, this is the most comprehensive study to date investigating the domain shift in deep learning on MRI data, and we advocate rigorous evaluation of DL models on clinical data prior to being certified for deployment.
Author(s): Martensson G, Ferreira D, Granberg T, Cavallin L, Oppedal K, Padovani A, Rektorova I, Bonanni L, Pardini M, Kramberger MG, Taylor J-P, Hort J, Snaedal J, Kulisevsky J, Blanc F, Antonini A, Mecocci P, Vellas B, Tsolaki M, Kloszewska I, Soininen H, Lovestone S, Simmons A, Aarsland D, Westman E
Publication type: Article
Publication status: Published
Journal: Medical Image Analysis
Year: 2020
Volume: 66
Print publication date: 01/02/2020
Online publication date: 01/05/2020
Acceptance date: 24/04/2020
ISSN (print): 1361-8415
ISSN (electronic): 1361-8423
Publisher: Elsevier B.V.
URL: https://doi.org/10.1016/j.media.2020.101714
DOI: 10.1016/j.media.2020.101714
PubMed id: 33007638
Altmetrics provided by Altmetric