© 2019 Institute of Advanced Engineering and Science. This paper presents the comparison between proportional integral (PI) current controller, proportional resonance and harmonic compensator (PR+HC) current controller and modified PR+HC current controller in the inverter system. Power electronic components like inverter and current controller uses in the system produce unwanted harmonics that affect the quality of distribution power network. In this study, development and simulation of current controller using conventional proportional integral (PI), the selective harmonic compensation scheme (PR+HC), and modified version of the latter are considered so to overcome these harmonics injection. Modification is by adding control parameter randomisation technique to the PR+HC scheme. Results compare the three controllers and proved that with modification to the selective harmonic compensation scheme, the overall current THD can be reduced.
Author(s): Salimin S, Armstrong M, Jumaat SA, Hamdan R
Publication type: Article
Publication status: Published
Journal: Indonesian Journal of Electrical Engineering and Computer Science
Year: 2019
Volume: 13
Issue: 3
Pages: 1167-1174
Online publication date: 01/03/2019
Acceptance date: 15/12/2018
Date deposited: 02/04/2019
ISSN (print): 2502-4752
ISSN (electronic): 2502-4760
Publisher: Institute of Advanced Engineering and Science
URL: https://doi.org/10.11591/ijeecs.v13.i3.pp1167-1174
DOI: 10.11591/ijeecs.v13.i3.pp1167-1174
Altmetrics provided by Altmetric