Toggle Main Menu Toggle Search

Open Access padlockePrints

Intra-and inter-observer reliability of nailfold videocapillaroscopy - A possible outcome measure for systemic sclerosis-related microangiopathy

Lookup NU author(s): Professor John AllenORCiD

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

© 2017 Elsevier Inc. Objectives Our aim was to assess the reliability of nailfold capillary assessment in terms of image evaluability, image severity grade (‘normal’, ‘early’, ‘active’, ‘late’), capillary density, capillary (apex) width, and presence of giant capillaries, and also to gain further insight into differences in these parameters between patients with systemic sclerosis (SSc), patients with primary Raynaud's phenomenon (PRP) and healthy control subjects. Methods Videocapillaroscopy images (magnification 300 ×) were acquired from all 10 digits from 173 participants: 101 patients with SSc, 22 with PRP and 50 healthy controls. Ten capillaroscopy experts from 7 European centres evaluated the images. Custom image mark-up software allowed extraction of the following outcome measures: overall grade (‘normal’, ‘early’, ‘active’, ‘late’, ‘non-specific’, or ‘ungradeable’), capillary density (vessels/mm), mean vessel apical width, and presence of giant capillaries. Results Observers analysed a median of 129 images each. Evaluability (i.e. the availability of measures) varied across outcome measures (e.g. 73.0% for density and 46.2% for overall grade in patients with SSc). Intra-observer reliability for evaluability was consistently higher than inter- (e.g. for density, intra-class correlation coefficient [ICC] was 0.71 within and 0.14 between observers). Conditional on evaluability, both intra- and inter-observer reliability were high for grade (ICC 0.93 and 0.78 respectively), density (0.91 and 0.64) and width (0.91 and 0.85). Conclusions Evaluability is one of the major challenges in assessing nailfold capillaries. However, when images are evaluable, the high intra- and inter-reliabilities suggest that overall image grade, capillary density and apex width have potential as outcome measures in longitudinal studies.


Publication metadata

Author(s): Dinsdale G, Moore T, O'Leary N, Tresadern P, Berks M, Roberts C, Manning J, Allen J, Anderson M, Cutolo M, Hesselstrand R, Howell K, Pizzorni C, Smith V, Sulli A, Wildt M, Taylor C, Murray A, Herrick AL

Publication type: Article

Publication status: Published

Journal: Microvascular Research

Year: 2017

Volume: 112

Pages: 1-6

Print publication date: 01/07/2017

Online publication date: 02/02/2017

Acceptance date: 01/02/2017

ISSN (print): 0026-2862

ISSN (electronic): 1095-9319

Publisher: Academic Press Inc.

URL: https://doi.org/10.1016/j.mvr.2017.02.001

DOI: 10.1016/j.mvr.2017.02.001


Altmetrics

Altmetrics provided by Altmetric


Share