Browse by author
Lookup NU author(s): Dr Richard Edwards
Full text for this publication is not currently held within this repository. Alternative links are provided below where available.
© Published by the BMJ Publishing Group Limited. Background While transcatheter aortic valve implantation (TAVI) is established for treating high-operative risk surgical aortic valve replacement candidates, until recently the smallest transcatheter heart valve (THV) measured 23 mm, posing greater risk for annular rupture and THV failure in patients with aortic stenosis (AS) with small aortic annuli (≤20 mm). Objectives In the setting of a multicentre registry, we report on the safety, efficacy and early clinical outcomes of the SAPIEN XT 20 mm balloon-expanding THV. Results Among TAVI 55 recipients (n=30 for native AS, n=25 for a valve-in-valve procedure (V-in-V)), median age and Society of Thoracic Surgeons score were 85 (81 to 87) years and 7.8 (4.7 to 12.4)%, respectively. Mean and minimum annular diameters were 19±1 and 17±2 mm, respectively, in native patients with AS, and 17±1 mm (internal diameter) in V-in-V recipients. Successful device implantation rate was 96%, with no procedural-related death. Overall in-hospital-30-day death, stroke and major bleeding rates were 5%, 2% and 9%, respectively. In native AS TAVI recipients, mean transaortic gradient decreased from 54±20 to 12±5 mm Hg (p<0.001), and from 45±17 to 24±8 mm Hg (p<0.001) in V-in-V recipients. Severe prosthesis-patient mismatch (PPM) rates were 10% and 48% in native AS and V-in-V TAVI recipients, respectively (p=0.03). Post-TAVI, the rate of moderate aortic regurgitation was 7% and 0% in native AS and V-in-V TAVI recipients, respectively. Conclusions TAVI with the 20 mm SAPIEN XT THV appears safe and technically feasible, with acceptable short-term clinical outcomes and low rates of severe PPM in those with native AS.
Author(s): Puri R, Byrne J, Muller R, Baumbach H, Eltchaninoff H, Redwood S, Cheema A, Dubois C, Ihlberg L, Wijeysundera HC, Cerillo A, Gotberg M, Klaaborg KE, Pelletier M, Blanco-Mata R, Edwards R, Gandolfo C, Muir D, Meucci F, Sinning J-M, Stella P, Veulemans V, Virtanen M, Regueiro A, Thoenes M, Pibarot P, Pelletier-Beaumont E, Rodes-Cabau J
Publication type: Article
Publication status: Published
Journal: Heart
Year: 2017
Volume: 103
Issue: 2
Pages: 148-153
Print publication date: 15/01/2017
Online publication date: 17/08/2016
Acceptance date: 13/07/2016
ISSN (print): 1355-6037
ISSN (electronic): 1468-201X
Publisher: BMJ Publishing Group
URL: https://doi.org/10.1136/heartjnl-2016-309707
DOI: 10.1136/heartjnl-2016-309707
Altmetrics provided by Altmetric