Browse by author
Lookup NU author(s): Professor Gerard Stansby, Dr Jonathan Smout
Full text for this publication is not currently held within this repository. Alternative links are provided below where available.
The use of radial artery catheters for real-time blood pressure monitoring and arterial blood gas sampling has become commonplace in both intensive care and high dependency units. Although this procedure is relatively safe, it can be complicated by local infection leading to pseudoaneurysm formation. In this report we describe three cases of pseudoaneurysm formation following prolonged radial catheter placement, with evidence of local methicillin resistant staphylococcus aureus (MRSA) infection. With the growing problem of in-hospital MRSA colonisation, the report aims to emphasize the need for vigilance for this complication and reinforce the importance of careful asepsis. In all cases the pseudoaneurysms were successfully treated with local ligation of the radial artery, without subsequent ischaemic complications. Allen's test was performed to ensure sufficient collateral circulation prior to surgery.
Author(s): Smout J; Stansby G; Chalmers R; Lintott R
Publication type: Article
Publication status: Published
Journal: Surgeon
Year: 2003
Volume: 1
Issue: 2
Pages: 108-110
ISSN (print): 1479-666X
Publisher: Elsevier Ltd
URL: http://dx.doi.org/10.1016/S1479-666X(03)80126-9
DOI: 10.1016/S1479-666X(03)80126-9
Notes: 1479-666x Case Reports Journal Article
Altmetrics provided by Altmetric