This paper reports on an investigation into the suitability of the Kodak DCS Pro Back for use in close range photogrammetric measurement. The camera back, being used in conjunction with a medium-format non-metric camera, has been assessed with a view to using it for low- to medium-order photogrammetric work in architectural recording. Examinations centred upon the stability of the camera back with respect to the camera body and the effects of the removable infrared filter that is present immediately above the camera focal plane. Ultimately the camera combination was deemed suitable for application in recording of this kind and is now in active use by the Metric Survey Team at English Heritage.
Author(s): Mills JP, Schneider D, Barber DM, Bryan PG
Publication type: Article
Publication status: Published
Journal: The Photogrammetric Record
Year: 2003
Volume: 18
Issue: 103
Pages: 193-208
ISSN (print): 0031-868X
ISSN (electronic): 1477-9730
URL: http://dx.doi.org/10.1111/0031-868X.t01-1-00019
DOI: 10.1111/0031-868X.t01-1-00019