Are fine needle breast aspirates representative of the underlying solid tumor: a comparison on receptor levels, ploidy and the influence of cytokeratin gates

Lookup NU author(s): Dr Ian Brotherick, Dr Brian Shenton, Professor Thomas Lennard

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

Fifty-three solid and 33 fine-needle aspirate (FNA) samples (20 paired) of human breast carcinomas were examined by flow cytometry. Experiments were conducted to assess whether FNA samples were phenotypically representative of the solid tumour. Quantitication of oestrogen receptor (ER), epidermal growth factor receptor (EGFR), c-erbB-2 receptor levels and ploidy were examined on the total and cytokeratin-positive cell populations. The absolute number of molecules of cytokeratin per cell expressed on the FNA (pr = 33) and solid tumour (pi = 53) samples showed no significant difference, but, on a proportional basis, there was a significant difference between the two samples (P = 0.004), with lower expression exhibited by the FNAs. Examination of paired data showed no significant difference in the percentage of cytokeratin-positive cells (P = 0.51) or in the number of cytokeratin molecules expressed (P = 0.25). While the correlation for ER expression between paired tumour and FNA samples in the absence of cytokeratin gating was P = 0.06, r(2) = 0.18, clear correlation was shown when a cytokeratin gate was used (P = 0.005, r(2) = 0.4). Repeating this experiment for EGFR, it was found that no correlation was seen between FNA and solid tumour (P = 0.2, r(2) = 0.14) in ungated populations, but use of the cytokeratin gate improved the correlation (P = 0.05, r(2) = 0.3). A similar finding was seen with c-erbB-2 expression (P = 0.2, r(2) = 0.1) without cytokeratin gating and when it was employed (P = 0.05, r(2) = 0.4). Ploidy data showed concordance in 18/20 cases. Three cases of aneuploidy were missed by FNA, and this was because of an insufficient number of cells for analysis. The presented data suggest that FNAs are representative of solid tumours and may be useful for measuring receptor levels on clinical material when cytokeratin gating is used. However, observation by light microscopy is still necessary to confirm the presence of tumour cells in FNAs subjected to how cytometry.


Publication metadata

Author(s): Brotherick I, Shenton BK, Lennard TWJ

Publication type: Article

Publication status: Published

Journal: British Journal of Cancer

Year: 1995

Volume: 72

Issue: 3

Pages: 732-737

Print publication date: 01/09/1995

ISSN (print): 0007-0920

ISSN (electronic): 1532-1827